MTA Monitoring Report 05/30/08 - 06/05/08

Archive of all weekly reports

Archive of monthly reports

Radiation

Quiet.

Detrended CTI

Although we have quoted CTI values of the cleanest data (FT <= -119.7 C, int time > 7000sec), the data fills these conditions are getting rare. From this week, we quote CTI temperature factor corrected ones. The values in the parentheses are CTI based on the cleanest data.

Average of ACIS-I CCDs (MnKa) slope: 1.514e-9 CTI/day (2.227e-9 CTI/day)
Detrended slope: 7.041e-9 CTI/day(7.427e-9 CTI/day)

ACIS Warm Pixels

We display all bad pixels showed up in past, and, if any, previously unknown bad pixels appeared in the last 14 days. We also list hot pixels (defined as 1000 above the average of bias background). Warm columns 509-514 are probably due to a computational artificial effect due to boundaries.


ACIS Focal Plane Temperature

SIM Movements

13 TSC moves this period
weekly average time/step 0.00135 s
mission average time/step 0.00135 s

Telemetry

New violations or new extrema are shown in blue cells.
MSID 05/30/08 05/31/08 06/01/08 06/02/08 06/03/08 06/04/08 06/05/08 yellow limits
(lower)
upper
red limits
(lower)
upper
Units Description
1CBAT (200.95) (203.40) (203.40) (200.95) (203.40) (203.40) (200.95) (210.0)
301.0
(205.0)
306.06
A CAMERA BODY TEMP.
1CBBT (200.95) (203.40) (203.40) (203.40) (203.40) (203.40) (203.40) (210.0)
301.0
(205.0)
306.06
B CAMERA BODY TEMP.
1WRAT (183.83)             (185.0)
323.0
(180.0)
360.06
A WARM RADIATOR TEMP.
1WRBT (183.83)             (185.0)
323.0
(180.0)
360.06
B WARM RADIATOR TEMP.
5EPHINT 318.56 318.14 318.14     315.16 318.56 (261.0)
300.0
(258.0)
303.0
TEMP EPHIN
HKEBOXTEMP 322.97 322.97 322.97     320.29 322.97 (268.0)
308.0
(253.0)
343.0
K EPHIN HOUSEKEEPING EBOX: TEMPERATURE (5EHSE300)
HKFBIASLEAKI 3.62 3.41 3.52 2.12   2.68 3.58 (-100.0)
2.0
(-200.0)
3.0
uA EPHIN HOUSEKEEPING F-BIAS: LEAKAGE CURRENT (5EHSE900)
TEIO           333.98 333.98 (253.0)
320.2
(250.2)
323.0
K EPHIN ELECTRONICS HOUSING TEMP
TEPHIN 319.42 318.59 318.59     316.12 318.59 (260.8)
300.2
(258.0)
303.0
TEMP EPHIN SENSOR HOUSING
TSCTABADC             (0.05) (4.82)
5.03
(4.80)
5.05
converter TSC Tab Position Sensor A/D
BOXTEMP       293.15       (225.2)
248.7
(223.2)
350.7
K SEA box temperature
ELBI   48.96 50.25         (17.0)
32.0
(3.0)
75.8
AMP LOAD BUS CURRENT
CSSR2CBV           4.96 4.96 (-1.0)
1.0
(-1.0)
1.0
V SSR-2 CONVERTER B VOLTAGE

IRUs


Recent Observations


OBSID DETECTOR GRATING TARGET ANALYSIS ACA
8931 ACIS-0123 NONE NGC 6611 OK OK
9242 ACIS-3678 NONE 3CRR 14 OK OK
9027 ACIS-3678 NONE NGC 1904 OK OK
9499 ACIS-012367 NONE Carina Superbubble Ptg 4 OK OK
9859 ACIS-012367 NONE Carina Superbubble Ptg 3 OK OK
9164 ACIS-012367 NONE J0447.8-4112 OK OK
9529 ACIS-012367 NONE M31 OK OK
7645 ACIS-7 NONE RRAT J1819-1458 OK OK
9611 ACIS-235678 NONE AX J183206-0938 OK OK
9615 ACIS-235678 NONE AX J191046+0917 OK OK
9439 ACIS-0123 NONE ESO 575-59 OK OK
9238 ACIS-23678 NONE RXJ1131-1231 OK OK
8917 ACIS-235678 NONE SDSS J1532+4727 OK OK
9314 ACIS-23567 NONE 3C323.1 OK OK
9258 ACIS-3678 NONE 3CRR 368 OK OK
9241 ACIS-3678 NONE 3CRR 13 OK OK
9293 ACIS-2367 NONE 3C18 OK OK
8932 ACIS-0123 NONE NGC 6611 OK OK
7516 ACIS-7 NONE XTE J1701-462 OK OK
9126 ACIS-235678 NONE SGR 1627-41 CC OK
9866 ACIS-01236 NONE AEGIS-1 OK OK
9319 ACIS-2367 NONE 3C460 OK OK
9098 ACIS-235678 NONE SN 2005db OK OK
9865 ACIS-0123 NONE NGC 6611 OK OK
9726 ACIS-01236 NONE AEGIS-1 OK OK

Trending

This week's focus is Ground Computations..

Trends last reported on Mar 06.

Only the most interesting or representative msids are shown below. For a full listing choose the bulletted link.

Min/max envelopes in dark blue appear on the trending plots. The envelopes are 4th degree fits to the monthly minimum and maximum values for each MSID. The final polynomial form and binning are still being experimented with. We will soon add to the trending pages a report of the fits and predictions they give on future limit violations. The light blue curve is our original smoothing of all the data over 30 day moving boxcars. The green/yellow line is a linear fit to all the data; the break occurs at a limit change.