MTA Monitoring Report 09/12/08 - 09/18/08

Archive of all weekly reports

Archive of monthly reports

Radiation

Quiet.

Detrended CTI

Although we have quoted CTI values of the cleanest data (FT <= -119.7 C, int time > 7000sec), the data fills these conditions are getting rare. From this week, we quote CTI temperature factor corrected ones. The values in the parentheses are CTI based on the cleanest data.

Average of ACIS-I CCDs (MnKa) slope: 1.430e-9 CTI/day (1.863e-9 CTI/day)
Detrended slope: 7.067e-9 CTI/day(7.320e-9 CTI/day)

ACIS Warm Pixels

We display all bad pixels showed up in past, and, if any, previously unknown bad pixels appeared in the last 14 days. We also list hot pixels (defined as 1000 above the average of bias background). Warm columns 509-514 are probably due to a computational artificial effect due to boundaries.


ACIS Focal Plane Temperature

SIM Movements

5 TSC moves this period
weekly average time/step 0.00131 s
mission average time/step 0.00134 s

Telemetry

New violations or new extrema are shown in blue cells.
MSID 09/12/08 09/13/08 09/14/08 09/15/08 09/16/08 09/17/08 09/18/08 yellow limits
(lower)
upper
red limits
(lower)
upper
Units Description
1CBAT (203.40) (203.40) (203.40) (203.40) (203.40) (203.40) (200.95) (210.0)
301.0
(205.0)
306.06
A CAMERA BODY TEMP.
1CBBT (203.40) (203.40) (203.40) (203.40) (203.40) (203.40) (203.40) (210.0)
301.0
(205.0)
306.06
B CAMERA BODY TEMP.
1CRAT           (142.83)   (143.0)
323.0
(138.0)
373.06
A COLD RADIATOR TEMP.
1CRBT           (142.83)   (143.0)
323.0
(138.0)
373.06
B COLD RADIATOR TEMP.
5EPHINT 318.99 316.43 316.43 316.01 313.88 315.58 316.01 (261.0)
300.0
(258.0)
303.0
TEMP EPHIN
HKEBOXTEMP 323.67 320.95 321.61 320.29 320.29   320.29 (268.0)
308.0
(253.0)
343.0
K EPHIN HOUSEKEEPING EBOX: TEMPERATURE (5EHSE300)
HKFBIASLEAKI 3.69 3.00 3.02 2.66 2.81 2.76 2.85 (-100.0)
2.0
(-200.0)
3.0
uA EPHIN HOUSEKEEPING F-BIAS: LEAKAGE CURRENT (5EHSE900)
TEIO 333.98 335.56 337.13 333.98 333.98 335.56 335.56 (253.0)
320.2
(250.2)
323.0
K EPHIN ELECTRONICS HOUSING TEMP
TEPHIN 318.59 317.77 317.77 317.77 315.29 316.12 316.94 (260.8)
300.2
(258.0)
303.0
TEMP EPHIN SENSOR HOUSING
CALPALV       (72.00)       (126.0)
128.0
(125.0)
129.0
V Cal pulser amplitude (2CALPALV)
RSRFALV       (141.00)       (172.0)
174.0
(171.0)
175.0
V Range switch setting (2RSRFALV)
PRBSCR       (0.01)       (1.239)
1.921
(0.898)
2.262
AMP Primary bus current (2PRBSCR)
PRBSVL       (6.56)       (23.0)
34.0
(22.0)
35.0
V Primary bus voltage (2PRBSVL)
SPINATM       (-30.96)       (-12.15)
34.85
(-15.15)
39.85
C Spect det temperature (2SPINATM)
LVPLATM       (-51.40)       (-32.15)
49.85
(-35.15)
54.85
C LVPS plate temperature (2LVPLATM)
SMTRATM       55.20       (-17.15)
44.85
(-20.15)
49.85
C Selected motor temperature (2SMTRATM)
3RCTUBPT     294.46 298.99 294.46 294.46   (234.1)
276.3
(231.6)
278.8
(+X) RCTU BASEPLATE
BOXTEMP   293.65   294.15 293.65 294.15   (225.2)
248.7
(223.2)
350.7
K SEA box temperature
TSCIUSF8       362.26       (230.2)
346.9
(227.4)
349.7
TEMP SC-IUS FITTING-8

IRUs


Recent Observations


OBSID DETECTOR GRATING TARGET ANALYSIS ACA
9490 ACIS-012367 NONE Carina East Ptg 3 OK OK
9454 ACIS-01236 NONE AEGIS-2 OK OK
9049 ACIS-012367 NONE IGR J13186-6257 OK OK
9555 ACIS-23678 NONE Sculptor Dwarf Galaxy OK OK
9066 ACIS-012367 NONE IGR J11098-6457 OK OK
9727 ACIS-01236 NONE AEGIS-2 OK OK
9455 ACIS-01236 NONE AEGIS-2 OK OK
9896 ACIS-23567 NONE Bootes Group 14 OK OK
9323 ACIS-23678 NONE SDSS J0900+3219 OK OK
9734 ACIS-01236 NONE AEGIS-3 OK OK
9221 ACIS-7 NONE PKS 0119-046 OK OK

Trending

This week's focus is HRMA Thermal Trends.

Last reported on Jun 26.

Only the most interesting or representative msids are shown below. For a full listing choose the bulletted link.

Min/max envelopes in dark blue appear on the trending plots. The envelopes are 4th degree fits to the monthly minimum and maximum values for each MSID. The final polynomial form and binning are still being experimented with. We will soon add to the trending pages a report of the fits and predictions they give on future limit violations. The light blue curve is our original smoothing of all the data over 30 day moving boxcars. The green/yellow line is a linear fit to all the data; the break occurs at a limit change.