MTA Monitoring Report 02/05/16 - 02/11/16

Archive of all weekly reports
Archive of monthly reports


Radiation

Quiet

Detrended CTI

Although we prefer to quote CTI values of the cleanest data (FT <= -119.7 C, int time > 7000sec), the data that fulfills these conditions are getting rare. We now quote CTI based on temperature corrected data for Focal plane temperature <= -118.5 C).

The unit is now CTI/year not CTI/day.

Average of ACIS-I CCDs (MnKa) slope: 1.431e-02 CTI/year (3.920e-05 CTI/day)
Detrended slope: 1.565e-02 CTI/year (4.288e-05 CTI/day)

ACIS Warm Pixels

We display all bad pixels that have showed up in past, and, if any, previously unknown bad pixels appeared in the last 14 days. We also list hot pixels (defined as 1000 above the average of bias background). Warm columns 509-514 are probably due to boundaries.

New definitions of warm pixels and flickering pixels (May 15, 2014). If a pixel displays the level beyond a threshold for more than 70% of the time in the past two weeks, the pixel is categorized as a "warm" pixel. If a pixel is above the threshold more than 30% of time but less than 70% of the time in the past two weeks, the pixel is categorized as a "flickering" pixel.

 CCD0CCD1CCD2CCD3CCD4CCD5CCD6CCD7CCD8CCD9
Previously Unknown Bad Pixels                    
Current Warm Pixels (153,205) (143,700) (692,141) (910,239) (802,665) (726,537) (21,95)       (335,412) (197,241) (881,53) (139,109)  
Flickering Warm Pixels     (526,66) (104,31) (811,637)   (669,577) (357,303) (282,385) (369,376) (728,340) (263,317) (367,511) (341,427) (161,206) (1000,214) (287,164) (884,31)   (737,382) (182,474) (356,902) (636,819)
Current Hot Pixels                    
Flickering Hot Pixels                    
Warm column candidates         884 510 512 1022   512 1022    
Flickering Warm Column Candidates                    

ACIS Focal Plane Temperature

For this period, 5 peaks are observed.

Weekly focal plane temperature with sun angle, earth angle, and altitude overplotted. Sun angle is the solar array angle, that is the angle between the sun and the optical axis (+X axis). The earth angle is the angle between earth and the ACIS radiator (+Z axis). Altitude varies from 34 kkm to 128 kkm.



SIM Movements

13 TSC moves this period

Telemetry

New violations or new extrema are shown in blue cells.

MSID 02/05/16 02/06/16 02/07/16 02/08/16 02/09/16 02/10/16 02/11/16 yellow limits
(lower)
upper
red limits
(lower)
upper
Units Description
1DAHBCU 0.46 0.56 0.52 0.52 0.60 0.48 0.48 (-998)
0.20
(-999)
999
AMP #DA HEATER CURRENT B
1DAHBVO 5.75 7.31 6.47 6.47 7.91 6.23 6.35 (-998)
1.0
(-999)
999
V #DA HEATER VOLTAGE B
1DAHHBVO 28.08 28.24 28.08 28.08 28.24 28.39 27.92 (-998)
1.0
(-999)
999
V #DA HOUSING HEATER INPUT VOLTAGE B
HRMACAV (284.85) (284.85) (284.85) (284.85) (284.85)   (284.85) (293.4)
294.8
(292.8)
295.5
TEMP # HRMA CAVITY AVG
MZOBACONE             (242.10) (260.2)
303.0
(250.2)
308.0
CONE # -Z SIDE OBA
PZOBACONE     (198.92)   (198.92)   (215.05) (260.2)
303.0
(250.2)
308.0
CONE # +Z SIDE OBA
TFTERANGE (0.00)         (0.00) (0.00) (16.7)
34.5
(11.1)
42.0
K # TFTE VENT/RAD TEMP
TFTERANGE 36.07 34.76   34.73   35.67 35.71 (16.7)
34.5
(11.1)
42.0
K # TFTE VENT/RAD TEMP
5EPHINT 348.28 340.12 337.94 339.03 340.67 345.63 346.96 (261.15)
331.15
(258.15)
341.15
K #EPHIN TEMP
HKP5V (5.06)         (5.06) (5.06) (5.08)
5.15
(5.06)
5.17
V #HK 5 Volts Rail - Voltage
HKP6V (5.73)             (5.75)
5.86
(5.74)
5.88
V #HK 6 Volts Rail - Voltage
HKEBOXTEMP 353.56 345.00 343.76 343.76 346.29 351.98 351.98 (268.15)
336.15
(253.15)
346.15
K #EPHIN HOUSEKEEPING EBOX: TEMPERATURE (5EHSE300)
TEIO 355.98 355.98 354.41 355.98 349.70 355.98 355.98 (252.15)
347.26
(249.37)
361.15
K #EPHIN ELECTRONICS HOUSING TEMP
TEPHIN 348.12         346.55 346.55 (259.93)
344.67
(257.15)
349.15
K #EPHIN SENSOR HOUSING TEMP
S2HVLV (83.00) (83.00) (83.00) (83.00) (83.00) (83.00) (83.00) (126.0)
128.0
(125.0)
129.0
(2S2HVLV) #Shield PMT 2 HV monitor
RSRFALV 190.00 190.00 190.00 190.00 190.00 190.00 190.00 (172.0)
174.0
(171.0)
175.0
V #Range switch setting (2RSRFALV)
3FLCABPT 293.45     293.95 293.45   293.45 (253.15)
293.15
(235.65)
310.65
K #FLCA BASEPLATE (+X)
3TSMXCET 275.78 278.28 278.28 278.28 278.28 270.79 265.81 (153.15)
263.15
(148.15)
353.15
K #-X TURTLE SHELL NR HRC CEA
3TSMXSPT 315.69 313.19 315.69 313.19 315.69 310.70 305.71 (203.15)
294.15
(148.15)
354.15
K #-X TURTLE SHELL NR ACIS SS
ELBV (27.73) (27.73) (27.58) (27.73) (27.58) (27.73) (27.73) (28.0)
32.50
(25.0)
34.60
V #LOAD BUS VOLTAGE
TCYLAFT6 316.12 311.56 311.56 310.86 310.86 312.95 314.47 (259.93)
309.93
(226.59)
348.82
K #CNT CYL TEMP:16-IN FWD OF SC-TS FIT-6
4PRT3AT 258.46 258.46 259.14 258.46 259.14 258.46 258.46 (204.37)
224.04
(132.15)
309.15
K #IP A: PRE-COLLIMATOR PRT 3 TEMPERATURE
4PRT5BT (147.25) (147.25) (147.25) (147.25) (147.25) (147.25) (147.25) (188.71)
290.09
(133.15)
308.15
K #IP B: PRE-COLLIMATOR PRT 5 TEMPERATURE


IRUs

Recent Observations

OBSID DETECTOR GRATING TARGET ANALYSIS ACA
18743 ACIS-5678 HETG HD191612 OK //Grat OK
17210 ACIS-01236 NONE SPT-CLJ0607-4448 OK OK
17867 ACIS-01236 NONE 3FGL J0827.2-0711 OK OK
18155 ACIS-23678 NONE LCRS B110045.0-063806 OK OK
17729 ACIS-2367 NONE 202059198 OK OK
18230 ACIS-5678 NONE J1146 OK OK
17842 ACIS-7 NONE SDSS J113017.5+385550.1 OK OK
18214 ACIS-678 NONE SDSSJ112104.93+432141.6 OK OK
16647 ACIS-0123 NONE 16 Cyg ABC OK OK
18102 ACIS-2367 NONE 3CR 255 OK OK
18291 ACIS-0123 NONE PSZ2 G213.39+80.59 OK OK
18756 ACIS-0123 NONE 16 Cyg ABC OK OK
18098 ACIS-2367 NONE 3CR 220.2 OK OK
18113 ACIS-678 NONE SDSS J1012+3244 OK OK
18115 ACIS-678 NONE SDSS J1223+1241 OK OK
18075 ACIS-235678 NONE ESO 500-34 OK OK
18154 ACIS-23678 NONE MCG -2-28-039 OK OK
18295 ACIS-0123 NONE PSZ2 G282.28+49.94 OK OK
17029 ACIS-678 NONE SDSS J1145+0322 OK OK
17181 ACIS-3 NONE RXCJ121510.9+073205 OK OK
17155 ACIS-01236 NONE RM J123416.1+151508.4 OK OK
17207 ACIS-012367 NONE RXC J1053.7+5452 WEST OK OK
17129 ACIS-23678 NONE 2XMM J123103.2+110648 OK OK
17153 ACIS-0123 NONE RM J113613.0+400235.8 OK OK
17090 ACIS-7 NONE 1642+690 OK OK

Trending

This week's focus is OBA Thermal

Last reported on Nov 19.

Only the most interesting or representative msids are shown below. For a full listing choose the bulletted link.

Min/max envelopes in dark blue appear on the trending plots. The envelopes are 4th degree fits to the monthly minimum and maximum values for each MSID. The final polynomial form and binning are still being experimented with. We will soon add to the trending pages a report of the fits and predictions they give on future limit violations. The light blue curve is our original smoothing of all the data over 30 day moving boxcars. The green/yellow line is a linear fit to all the data; the break occurs at a limit change.







If you have any questions, please contact: swolk@head.cfa.harvard.edu