MTA Monitoring Report 02/10/17 - 02/16/17

Archive of all weekly reports
Archive of monthly reports


Radiation

Quiet

Detrended CTI

Although we prefer to quote CTI values of the cleanest data (FT <= -119.7 C, int time > 7000sec), the data that fulfills these conditions are getting rare. We now quote CTI based on temperature corrected data for Focal plane temperature <= -118.5 C).

The unit is now CTI/year not CTI/day.

Average of ACIS-I CCDs (MnKa) slope: 1.289e-02 CTI/year (3.531e-05 CTI/day)
Detrended slope: 1.531e-02 CTI/year (4.193e-05 CTI/day)

ACIS Warm Pixels

We display all bad pixels that have showed up in past, and, if any, previously unknown bad pixels appeared in the last 14 days. We also list hot pixels (defined as 1000 above the average of bias background). Warm columns 509-514 are probably due to boundaries.

New definitions of warm pixels and flickering pixels (May 15, 2014). If a pixel displays the level beyond a threshold for more than 70% of the time in the past two weeks, the pixel is categorized as a "warm" pixel. If a pixel is above the threshold more than 30% of time but less than 70% of the time in the past two weeks, the pixel is categorized as a "flickering" pixel.

 CCD0CCD1CCD2CCD3CCD4CCD5CCD6CCD7CCD8CCD9
Previously Unknown Bad Pixels                    
Current Warm Pixels       (680,391) (847,364) (21,95)   (161,206)   (335,412) (182,474) (197,241) (139,109)  
Flickering Warm Pixels (692,141) (153,205) (143,700) (910,239) (802,665) (726,537) (318,53)   (607,281) (357,303) (282,385) (369,376) (669,577) (263,317) (367,511) (258,797) (341,427) (1000,214)   (881,53)  
Current Hot Pixels                    
Flickering Hot Pixels                    
Warm column candidates           510 512 1022   512 1022    
Flickering Warm Column Candidates                    

ACIS Focal Plane Temperature

For this period, 6 peaks are observed.

Weekly focal plane temperature with sun angle, earth angle, and altitude overplotted. Sun angle is the solar array angle, that is the angle between the sun and the optical axis (+X axis). The earth angle is the angle between earth and the ACIS radiator (+Z axis). Altitude varies from 34 kkm to 128 kkm.



SIM Movements

17 TSC moves this period

Telemetry

New violations or new extrema are shown in blue cells.

MSID 02/10/17 02/11/17 02/12/17 02/13/17 02/14/17 02/15/17 02/16/17 yellow limits
(lower)
upper
red limits
(lower)
upper
Units Description
HRMACAV     (284.85) (284.85) (284.85) (284.85) (284.85) (293.4)
294.8
(292.8)
295.5
TEMP # HRMA CAVITY AVG
MZOBACONE     (221.33)         (260.2)
303.0
(250.2)
308.0
CONE # -Z SIDE OBA
PZOBACONE     (198.92)         (260.2)
303.0
(250.2)
308.0
CONE # +Z SIDE OBA
TFTERANGE   (0.00) (0.00)   (0.00)     (16.7)
34.5
(11.1)
42.0
K # TFTE VENT/RAD TEMP
TFTERANGE 36.48 36.21 35.31 36.21 37.10 36.89 36.80 (16.7)
34.5
(11.1)
42.0
K # TFTE VENT/RAD TEMP
SCSTRUTRNGE           22.67   (-0.5)
22.2
(-1.0)
38.8
K # SC STRUT TEMP
5EPHINT 345.63 344.96 339.03 349.61 351.60 348.95 349.61 (261.15)
300.15
(258.15)
303.15
K #EPHIN TEMP
HKP5V (5.06) (5.06)   (5.06) (5.06) (5.06) (5.06) (5.08)
5.15
(5.06)
5.17
V #HK 5 Volts Rail - Voltage
HKP6V       (5.73) (5.73)   (5.73) (5.75)
5.86
(5.74)
5.88
V #HK 6 Volts Rail - Voltage
HKEBOXTEMP 351.98 350.47 343.76 355.21 356.95 355.21 355.21 (268.15)
336.15
(253.15)
346.15
K #EPHIN HOUSEKEEPING EBOX: TEMPERATURE (5EHSE300)
SPHBLV (78.00)         (78.00) (78.00) (79.0)
128.0
(78.0)
129.0
(2SPHBLV) #Spect bot and top MCP HV monitor
SPHBLV 146.00         130.00   (79.0)
128.0
(78.0)
129.0
(2SPHBLV) #Spect bot and top MCP HV monitor
S2HVLV (82.00) (83.00) (83.00) (83.00) (83.00) (82.00) (83.00) (126.0)
128.0
(125.0)
129.0
(2S2HVLV) #Shield PMT 2 HV monitor
RSRFALV (87.00)         (22.00)   (172.0)
174.0
(171.0)
175.0
V #Range switch setting (2RSRFALV)
3FLCABPT 293.45     293.45 295.97     (253.15)
293.15
(235.65)
310.65
K #FLCA BASEPLATE (+X)
3TSMXCET 278.28 278.28 280.77 280.77 278.28 278.28 280.77 (153.15)
263.15
(148.15)
353.15
K #-X TURTLE SHELL NR HRC CEA
3TSMXSPT 318.18 315.69 315.69 318.18 315.69 313.19 318.18 (203.15)
283.15
(148.15)
353.15
K #-X TURTLE SHELL NR ACIS SS
3TSPZSPT         295.74     (233.15)
293.15
(148.15)
353.15
K #+Z TURTLE SHELL NR ACIS SS
ELBV (27.58) (27.58) (27.73) (27.89) (27.73) (27.89) (27.89) (28.0)
32.5
(25.0)
34.6
V #LOAD BUS VOLTAGE
TAPE2PST (294.00) (293.57)     (293.57) (294.00) (293.57) (323.15)
330.15
(318.15)
335.15
K #PEA-2 POWER SUPPLY TEMP
4PRT3AT (258.46) (259.81) (258.46) (258.46) (258.46) (258.46) (258.46) (273.15)
283.15
(53.15)
368.15
K #IP A: PRE-COLLIMATOR PRT 3 TEMPERATURE


IRUs

Recent Observations

OBSID DETECTOR GRATING TARGET ANALYSIS ACA
18279 ACIS-01235 NONE Abell 586 OK OK
19381 ACIS-2367 NONE NGC 3583 OK OK
19967 HRC-S LETG IRAS 17020+4544 OK OK
19429 ACIS-5678 NONE NGC 4411b OK OK
20007 ACIS-0123 NONE LEDA 87445 OK OK
19483 ACIS-5678 NONE spog5260 OK OK
20003 ACIS-01235 NONE Abell 586 OK OK
20004 ACIS-01235 NONE Abell 586 OK OK
19404 ACIS-5678 NONE NGC 4237 OK OK
19989 ACIS-0123 NONE Cygnus A - Nucleus OK OK
18996 ACIS-01236 NONE AX J1753.5-2745 OK OK
18277 ACIS-0123 NONE MOOJ1142+1527 OK OK
19557 ACIS-23678 NONE SDSSJ152654.61+565512.3 OK OK
19985 ACIS-35678 NONE CSS161010 OK OK
19395 ACIS-5678 NONE NGC 4212 OK OK
20009 ACIS-5678 NONE Mrk 273 OK OK
19368 ACIS-2367 NONE NGC 3675 OK OK
18273 ACIS-0123 NONE Coma cluster OK OK
19457 ACIS-7 NONE M87 OK OK
19017 HRC-S LETG YZ Cnc OK OK
19414 ACIS-5678 NONE NGC 4312 OK OK
18178 ACIS-5678 NONE Mrk 273 OK OK
19458 ACIS-7 NONE M87 OK OK

Trending

This week's focus is HRC

Last reported on Nov 24.

Only the most interesting or representative msids are shown below. For a full listing choose the bulletted link.

Min/max envelopes in dark blue appear on the trending plots. The envelopes are 4th degree fits to the monthly minimum and maximum values for each MSID. The final polynomial form and binning are still being experimented with. We will soon add to the trending pages a report of the fits and predictions they give on future limit violations. The light blue curve is our original smoothing of all the data over 30 day moving boxcars. The green/yellow line is a linear fit to all the data; the break occurs at a limit change.