See http://cxc.harvard.edu/mta/SOT_reports/sot-shift.html Shift Report H6462 Start at 2017:091:01:00:00 GMT = 9:05pm March 31 2017 End at 2017:091:01:26:00 GMT = 9:26pm March 31 2017 ACIS SOT Shift Report March 10 2014 H6462. ACIS Personnel: Gregg Germain, Dick Edgar, Paul Plucinsky, Catherine Grant, John Zuhone PLAN -------- We ran CAP1415 to execute a 24 hour CTI measurement during a Bright Star Hold Shutdown. The Obsid for this measurement is: 62662 CLD File executed: 1A_4_CTI_24H_135.cld SUMMARY: -------- The CAP exactly as expected. TIMELINE (GMT day 90-91) ---------------------- 091:00:20 AOS on DSS 65 091:01:00 Verified radiation levels acceptable 091:01:01 Format 2 Verified 091:01:02 SCS-107 enabled 091:01:03 Obsid set to 62662 091:01:04 1A_4_CTI_24H_135.cld uploaded 091:01:06 SCS-135 enabled and activated 091:01:07 LOAD_TE observed 091:01:07 1STAT1ST bit changed from 1 to 0 indicating science run started 091:01:07 1DPICACU/1DPICBCU currents rose to correct values 091:01:07 System configuration and Huffman table dumped 091:01:21 Bias run begins 091:01:26 LOS; Bias runs for 2 chips complete; bias run for 3rd chip almost complete 091:01:30 Temperatures all normal. FP_TEMP = -199.7