Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
1dahacu -5.448e-086.458e-08(2.03+/-63.66)e-5(4.87+/-82.56)e-8AMPDA HEATER CURRENT ANo Violation Check
1dahavo 0.000e+000.000e+00(0.00+/-0.00)e0(0.00+/-0.00)e0VDETECTOR ASSY. HTRNo Violation Check
1dahhavo -7.185e-075.422e-07(1.80+/-50.00)e-4-(3.28+/-11.26)e-6VDA HOUSING HTR +28V INPUT ANo Violation Check
1de28avo -0.0014.721e-0526.59 +/- 0.48-0.01 +/- 0.01VDEA +28V INPUT ANo Violation Check
1deicacu 1.075e-043.136e-052.03 +/- 0.31-0.01 +/- 0.01AMPDEA INPUT CURRENT ANo Violation Check
1den0avo -4.155e-058.905e-06-6.20 +/- 0.090.00 +/- 0.00VDEA -6V VOLTAGE ANo Violation Check
1den1avo -1.006e-042.890e-05-15.61 +/- 0.290.00 +/- 0.01VDEA -15V VOLTAGE ANo Violation Check
1dep0avo 1.398e-054.006e-066.16 +/- 0.04-0.00 +/- 0.00VDEA +6V VOLTAGE ANo Violation Check
1dep1avo 8.311e-052.526e-0515.77 +/- 0.25-0.01 +/- 0.01VDEA +15V ANALOG ANo Violation Check
1dep2avo 7.870e-061.486e-0524.80 +/- 0.15-0.00 +/- 0.00VDEA +24V ANALOG ANo Violation Check
1dep3avo 1.264e-054.672e-0630.61 +/- 0.05-0.00 +/- 0.00VDEA +28V ANALOG ANo Violation Check
1dp28avo -0.0014.708e-0526.62 +/- 0.48-0.02 +/- 0.01VDPA +28V INPUT ANo Violation Check
1dpicacu 1.495e-042.283e-051.19 +/- 0.23-0.01 +/- 0.00AMPDPA INPUT CURRENT ANo Violation Check
1dpp0avo 1.480e-053.793e-065.28 +/- 0.04-(6.74+/-7.77)e-4VDPA +5V ANALOG ANo Violation Check