Back to Top

ACISELECA
Static Version: Min --- Last Three Months

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
1dahacu 0.000e+000.000e+00(0.00+/-0.00)e0(0.00+/-0.00)e0AMPDA HEATER CURRENT ANo Violation Check
1dahavo 0.000e+000.000e+00(0.00+/-0.00)e0(0.00+/-0.00)e0VDETECTOR ASSY. HTRNo Violation Check
1dahhavo 0.000e+000.000e+00(0.00+/-0.00)e0(0.00+/-0.00)e0VDA HOUSING HTR +28V INPUT ANo Violation Check
1de28avo 0.0049.176e-0525.73 +/- 0.28(4.12+/-242.70)e-4VDEA +28V INPUT ANo Violation Check
1deicacu -6.724e-051.424e-040.66 +/- 0.330.02 +/- 0.08AMPDEA INPUT CURRENT ANo Violation Check
1den0avo -8.793e-053.405e-05-6.32 +/- 0.08-0.01 +/- 0.02VDEA -6V VOLTAGE ANo Violation Check
1den1avo -2.991e-041.176e-04-15.83 +/- 0.28-0.02 +/- 0.06VDEA -15V VOLTAGE ANo Violation Check
1dep0avo 2.967e-051.542e-056.11 +/- 0.040.01 +/- 0.01VDEA +6V VOLTAGE ANo Violation Check
1dep1avo 2.397e-041.128e-0415.59 +/- 0.260.07 +/- 0.06VDEA +15V ANALOG ANo Violation Check
1dep2avo 5.379e-046.084e-0524.55 +/- 0.140.01 +/- 0.03VDEA +24V ANALOG ANo Violation Check
1dep3avo 1.208e-051.679e-0530.44 +/- 0.04-(2.37+/-45.90)e-4VDEA +28V ANALOG ANo Violation Check
1dp28avo 0.0049.095e-0525.75 +/- 0.28-0.01 +/- 0.02VDPA +28V INPUT ANo Violation Check
1dpicacu -3.769e-051.112e-040.98 +/- 0.260.04 +/- 0.04AMPDPA INPUT CURRENT ANo Violation Check
1dpp0avo 7.757e-061.048e-055.20 +/- 0.030.00 +/- 0.00VDPA +5V ANALOG ANo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: May 16, 2026
Last Site Modification: Sep 30, 2021