| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | -0.083 | 0.024 | (2.11+/-0.02)e2 | 43.79 +/- 92.33 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | -0.108 | 0.026 | (2.12+/-0.02)e2 | -11.64 +/- 127.14 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | -0.030 | 0.039 | (1.53+/-0.03)e2 | -(1.38+/-2.36)e2 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 4.653e-10 | 2.326e-06 | (6.78+/-0.00)e2 | (3.24+/-1.46)e-7 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.134 | 0.045 | (2.63+/-0.04)e2 | -(2.19+/-1.52)e2 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 0.084 | 0.066 | (2.88+/-0.05)e2 | -(1.09+/-0.49)e3 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | -0.311 | 0.067 | (2.88+/-0.05)e2 | -(1.33+/-0.48)e3 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.197 | 0.064 | (2.91+/-0.05)e2 | -(1.25+/-0.46)e3 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.033 | 0.033 | (2.50+/-0.03)e2 | 0.79 +/- 126.36 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.009 | 0.031 | (2.46+/-0.02)e2 | 58.09 +/- 80.68 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | 1.903 | 0.103 | (3.04+/-0.09)e2 | (8.55+/-2.65)e2 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | 1.807 | 0.102 | (2.98+/-0.09)e2 | (9.41+/-2.74)e2 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | -1.441 | 0.086 | (3.43+/-0.07)e2 | -(1.85+/-0.81)e2 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | -0.119 | 0.024 | (1.94+/-0.02)e2 | -3.20 +/- 153.40 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | -0.100 | 0.024 | (1.94+/-0.02)e2 | -60.84 +/- 162.33 | K | WARM RADIATOR TEMP. B | No Violation Check |