| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | -0.213 | 0.017 | (2.12+/-0.02)e2 | -84.52 +/- 84.92 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | -0.246 | 0.017 | (2.12+/-0.02)e2 | -(1.34+/-0.85)e2 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | -0.149 | 0.044 | (1.52+/-0.04)e2 | -(2.98+/-2.20)e2 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 2.701 | 1.824 | (5.13+/-1.70)e2 | (2.32+/-1.20)e4 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | -0.231 | 0.044 | (2.65+/-0.04)e2 | 71.78 +/- 117.06 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | -0.425 | 0.052 | (2.88+/-0.05)e2 | 41.54 +/- 356.84 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | -0.754 | 0.065 | (2.86+/-0.06)e2 | (2.69+/-4.41)e2 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.653 | 0.059 | (2.90+/-0.06)e2 | (2.31+/-4.04)e2 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | -0.143 | 0.028 | (2.51+/-0.03)e2 | -42.31 +/- 76.81 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | -0.209 | 0.027 | (2.47+/-0.03)e2 | -28.30 +/- 69.57 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -1.114 | 0.045 | (3.07+/-0.05)e2 | (5.00+/-2.02)e2 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -1.092 | 0.045 | (3.01+/-0.05)e2 | (3.50+/-1.91)e2 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 4.454e-10 | 1.016e-06 | (3.45+/-0.00)e2 | -(6.02+/-17.30)e-8 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | -0.225 | 0.020 | (1.94+/-0.02)e2 | -(2.72+/-1.23)e2 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | -0.207 | 0.019 | (1.94+/-0.02)e2 | -(2.54+/-1.23)e2 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Aug 16, 2026
Last Site Modification: Sep 30, 2021