| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | -7.421e-04 | 9.332e-05 | (2.12+/-0.02)e2 | -0.05 +/- 0.03 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | -7.194e-04 | 9.356e-05 | (2.13+/-0.02)e2 | -0.02 +/- 0.03 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | -3.261e-04 | 1.772e-04 | (1.55+/-0.04)e2 | 0.02 +/- 0.05 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 0.015 | 0.001 | (6.74+/-0.30)e2 | 0.01 +/- 0.10 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | -0.002 | 1.615e-04 | (2.64+/-0.04)e2 | -0.03 +/- 0.07 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 2.465e-04 | 2.792e-04 | (2.91+/-0.07)e2 | -0.10 +/- 0.06 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 4.500e-04 | 2.837e-04 | (2.91+/-0.07)e2 | -0.00 +/- 0.06 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | 4.791e-04 | 2.783e-04 | (2.94+/-0.07)e2 | -0.02 +/- 0.06 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | -0.001 | 1.171e-04 | (2.50+/-0.03)e2 | -0.03 +/- 0.05 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | -0.001 | 1.104e-04 | (2.46+/-0.03)e2 | -0.03 +/- 0.04 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -0.002 | 2.385e-04 | (3.05+/-0.06)e2 | -0.11 +/- 0.08 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -0.002 | 2.333e-04 | (2.99+/-0.06)e2 | -0.12 +/- 0.07 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 8.883e-04 | 1.057e-04 | (3.45+/-0.03)e2 | -(1.54+/-83.48)e-4 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | -4.860e-04 | 9.513e-05 | (1.95+/-0.02)e2 | -0.03 +/- 0.03 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | -5.117e-04 | 9.652e-05 | (1.95+/-0.02)e2 | -0.02 +/- 0.03 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: May 16, 2026
Last Site Modification: Sep 30, 2021