| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.558 | 0.027 | (2.13+/-0.03)e2 | (1.88+/-0.88)e2 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 0.573 | 0.027 | (2.14+/-0.03)e2 | (1.68+/-0.97)e2 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.406 | 0.037 | (1.54+/-0.03)e2 | (2.38+/-1.97)e2 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 0.178 | 0.098 | (6.78+/-0.08)e2 | (6.09+/-8.01)e-7 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.705 | 0.046 | (2.64+/-0.04)e2 | (1.86+/-1.03)e2 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 1.102 | 0.070 | (2.91+/-0.06)e2 | (9.18+/-5.01)e2 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 0.908 | 0.076 | (2.91+/-0.07)e2 | (3.56+/-5.38)e2 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | 0.909 | 0.073 | (2.94+/-0.07)e2 | (4.35+/-5.18)e2 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.665 | 0.034 | (2.51+/-0.03)e2 | (1.57+/-0.72)e2 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.585 | 0.032 | (2.47+/-0.03)e2 | (2.17+/-0.64)e2 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -0.351 | 0.058 | (3.05+/-0.05)e2 | (5.11+/-2.14)e2 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -0.384 | 0.058 | (2.98+/-0.05)e2 | (4.99+/-2.09)e2 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 7.180e-04 | 3.491e-04 | (3.45+/-0.00)e2 | (2.19+/-3.90)e-7 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.457 | 0.024 | (1.95+/-0.02)e2 | (1.55+/-1.20)e2 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.471 | 0.024 | (1.95+/-0.02)e2 | (1.83+/-1.20)e2 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Dec 24, 2025
Last Site Modification: Sep 30, 2021