Back to Top

ACISTEMP
Static Version: Mean --- One Week

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
1cbat 0.0970.022(2.13+/-0.02)e2-(1.21+/-0.95)e2KCAMERA BODY TEMP. ANo Violation Check
1cbbt 0.0910.021(2.13+/-0.02)e2-(1.92+/-0.90)e2KCAMERA BODY TEMP. BNo Violation Check
1crat 0.2330.051(1.54+/-0.05)e2(1.55+/-2.19)e2KCOLD RADIATOR TEMP. ANo Violation Check
1crbt 0.6750.489(6.68+/-0.46)e2(7.53+/-14.73)e2KCOLD RADIATOR TEMP. BNo Violation Check
1dactbt -0.1360.041(2.63+/-0.04)e2(1.01+/-1.05)e2KDA COLLIMATOR TEMP. BNo Violation Check
1deamzt -0.1790.072(2.90+/-0.07)e2(4.57+/-4.38)e2KDEA -Z PANEL TEMPNo Violation Check
1dpamyt -0.1600.072(2.90+/-0.07)e2(6.08+/-4.30)e2KDPA -Y PANEL TEMPNo Violation Check
1dpamzt -0.1480.071(2.93+/-0.07)e2(6.42+/-4.24)e2KDPA -Z PANEL TEMPNo Violation Check
1oahat -0.0450.027(2.50+/-0.02)e2-(1.21+/-0.72)e2KOPEN ACTUATOR HOUSING TEMP. ANo Violation Check
1oahbt -6.012e-040.025(2.46+/-0.02)e2-(1.39+/-0.61)e2KOPEN ACTUATOR HOUSING TEMP. BNo Violation Check
1pdeaat 0.1730.047(3.04+/-0.04)e2-59.88 +/- 204.51KPSMC DEA PS A TEMPNo Violation Check
1pdeabt 0.2550.046(2.96+/-0.04)e2-(2.07+/-1.98)e2KPSMC DEA PS B TEMPNo Violation Check
1pin1at 5.802e-111.015e-06(3.45+/-0.00)e2(1.01+/-0.19)e-7KPSMC TEMP 1ANo Violation Check
1wrat 0.0660.024(1.95+/-0.02)e2-86.51 +/- 134.47KWARM RADIATOR TEMP. ANo Violation Check
1wrbt 0.0550.024(1.95+/-0.02)e2-(2.09+/-1.31)e2KWARM RADIATOR TEMP. BNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.