| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | -0.144 | 0.019 | (2.12+/-0.02)e2 | -(1.47+/-0.89)e2 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | -0.161 | 0.021 | (2.13+/-0.02)e2 | -(1.50+/-0.97)e2 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.028 | 0.038 | (1.54+/-0.04)e2 | -(3.86+/-2.20)e2 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 6.032 | 1.102 | (4.43+/-1.03)e2 | (1.38+/-0.62)e4 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | -0.506 | 0.042 | (2.62+/-0.04)e2 | -88.75 +/- 102.69 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 0.043 | 0.080 | (2.90+/-0.07)e2 | (8.20+/-5.40)e2 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | -0.103 | 0.076 | (2.91+/-0.07)e2 | (3.80+/-5.20)e2 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.041 | 0.077 | (2.94+/-0.07)e2 | (6.20+/-5.18)e2 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | -0.325 | 0.028 | (2.50+/-0.03)e2 | -(2.20+/-0.69)e2 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | -0.331 | 0.027 | (2.46+/-0.03)e2 | -(1.42+/-0.58)e2 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | 0.072 | 0.055 | (3.07+/-0.05)e2 | -(1.48+/-2.08)e2 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | 0.152 | 0.052 | (2.99+/-0.05)e2 | (1.48+/-2.05)e2 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | -0.002 | 0.001 | (3.45+/-0.00)e2 | -(1.90+/-2.32)e-7 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | -0.073 | 0.022 | (1.95+/-0.02)e2 | -(2.03+/-1.32)e2 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | -0.065 | 0.022 | (1.95+/-0.02)e2 | -(1.77+/-1.32)e2 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Oct 27, 2026
Last Site Modification: Sep 30, 2021