Back to Top

ACISTEMP
Static Version: Mean --- One Week

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
1cbat -0.0810.022(2.11+/-0.02)e2-31.38 +/- 99.13KCAMERA BODY TEMP. ANo Violation Check
1cbbt -0.0960.023(2.12+/-0.02)e2-57.21 +/- 113.28KCAMERA BODY TEMP. BNo Violation Check
1crat 0.0220.036(1.53+/-0.03)e2-27.77 +/- 221.92KCOLD RADIATOR TEMP. ANo Violation Check
1crbt -5.3061.365(4.64+/-1.25)e2-(7.44+/-8.08)e3KCOLD RADIATOR TEMP. BNo Violation Check
1dactbt -0.1680.049(2.62+/-0.04)e2-(3.30+/-1.36)e2KDA COLLIMATOR TEMP. BNo Violation Check
1deamzt 0.0060.075(2.89+/-0.07)e2-(6.75+/-5.13)e2KDEA -Z PANEL TEMPNo Violation Check
1dpamyt -0.1000.077(2.88+/-0.07)e2-(4.93+/-5.30)e2KDPA -Y PANEL TEMPNo Violation Check
1dpamzt -0.0760.075(2.91+/-0.07)e2-(7.07+/-5.15)e2KDPA -Z PANEL TEMPNo Violation Check
1oahat -0.0510.033(2.49+/-0.03)e2-(1.58+/-0.80)e2KOPEN ACTUATOR HOUSING TEMP. ANo Violation Check
1oahbt -0.0880.030(2.45+/-0.03)e2-(1.03+/-0.71)e2KOPEN ACTUATOR HOUSING TEMP. BNo Violation Check
1pdeaat 0.5350.050(3.04+/-0.05)e2(2.28+/-2.18)e2KPSMC DEA PS A TEMPNo Violation Check
1pdeabt 0.5910.048(2.97+/-0.05)e238.01 +/- 200.39KPSMC DEA PS B TEMPNo Violation Check
1pin1at 5.264e-101.030e-06(3.45+/-0.00)e2(2.38+/-1.95)e-7KPSMC TEMP 1ANo Violation Check
1wrat -0.0790.021(1.94+/-0.02)e2-64.72 +/- 143.26KWARM RADIATOR TEMP. ANo Violation Check
1wrbt -0.0630.022(1.94+/-0.02)e2-65.32 +/- 139.79KWARM RADIATOR TEMP. BNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Sep 28, 2026
Last Site Modification: Sep 30, 2021