| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.581 | 0.020 | (2.09+/-0.03)e2 | -1.07 +/- 1.00 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 0.598 | 0.020 | (2.10+/-0.03)e2 | -0.55 +/- 0.99 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.444 | 0.025 | (1.48+/-0.03)e2 | 0.56 +/- 1.08 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 96.655 | 1.377 | (3.52+/-2.47)e2 | 9.88 +/- 25.56 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.553 | 0.034 | (2.57+/-0.04)e2 | -1.19 +/- 1.40 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | -0.052 | 0.045 | (2.83+/-0.05)e2 | 0.18 +/- 1.65 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | -0.041 | 0.048 | (2.83+/-0.06)e2 | 0.92 +/- 1.86 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.043 | 0.044 | (2.86+/-0.05)e2 | -0.30 +/- 1.69 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.207 | 0.027 | (2.44+/-0.02)e2 | 0.92 +/- 0.86 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.573 | 0.023 | (2.42+/-0.03)e2 | -0.84 +/- 1.10 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | 0.015 | 0.047 | (2.97+/-0.06)e2 | 0.95 +/- 2.02 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -0.123 | 0.046 | (2.88+/-0.05)e2 | 1.23 +/- 1.99 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 2.024 | 0.100 | (3.39+/-0.12)e2 | -0.95 +/- 3.65 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.494 | 0.019 | (1.92+/-0.02)e2 | -0.68 +/- 0.90 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.521 | 0.019 | (1.91+/-0.02)e2 | -0.50 +/- 0.91 | K | WARM RADIATOR TEMP. B | No Violation Check |