| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | -0.030 | 0.005 | (2.08+/-0.04)e2 | 0.10 +/- 0.06 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | -0.106 | 0.006 | (2.09+/-0.05)e2 | 0.13 +/- 0.06 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.124 | 0.004 | (1.46+/-0.03)e2 | 0.18 +/- 0.05 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 10.130 | 0.172 | (2.02+/-1.61)e2 | 2.36 +/- 0.35 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.095 | 0.007 | (2.55+/-0.05)e2 | 0.28 +/- 0.07 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 0.136 | 0.005 | (2.82+/-0.04)e2 | 0.29 +/- 0.10 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 0.067 | 0.006 | (2.83+/-0.05)e2 | 0.28 +/- 0.12 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | 0.054 | 0.005 | (2.86+/-0.04)e2 | 0.25 +/- 0.11 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.037 | 0.005 | (2.43+/-0.03)e2 | 0.01 +/- 0.06 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.130 | 0.003 | (2.40+/-0.03)e2 | 0.16 +/- 0.06 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -0.085 | 0.008 | (2.97+/-0.06)e2 | -0.11 +/- 0.17 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -0.044 | 0.007 | (2.88+/-0.06)e2 | -0.08 +/- 0.17 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 2.732 | 0.019 | (3.05+/-0.26)e2 | 0.23 +/- 0.27 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.061 | 0.004 | (1.90+/-0.03)e2 | 0.13 +/- 0.05 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.064 | 0.004 | (1.90+/-0.03)e2 | 0.11 +/- 0.05 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Jan 12, 2026
Last Site Modification: Sep 30, 2021