| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.212 | 0.024 | (2.13+/-0.02)e2 | -71.85 +/- 71.47 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 0.143 | 0.023 | (2.14+/-0.02)e2 | -96.31 +/- 104.83 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.086 | 0.037 | (1.54+/-0.03)e2 | -89.39 +/- 213.10 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | -6.361 | 0.915 | (4.19+/-0.86)e2 | -(2.10+/-3.89)e3 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.490 | 0.042 | (2.64+/-0.04)e2 | -(2.58+/-1.48)e2 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 0.265 | 0.072 | (2.92+/-0.07)e2 | -97.34 +/- 541.68 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | -0.466 | 0.072 | (2.91+/-0.07)e2 | -(4.66+/-5.64)e2 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.303 | 0.070 | (2.94+/-0.07)e2 | -(4.73+/-5.53)e2 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.360 | 0.030 | (2.50+/-0.03)e2 | -(2.11+/-0.94)e2 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.332 | 0.029 | (2.46+/-0.03)e2 | -(2.07+/-0.98)e2 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | 1.069 | 0.058 | (3.07+/-0.06)e2 | (3.73+/-2.19)e2 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | 1.077 | 0.057 | (2.98+/-0.06)e2 | (2.88+/-2.18)e2 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | -0.111 | 0.034 | (3.45+/-0.03)e2 | (6.47+/-26.08)e-8 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.125 | 0.024 | (1.95+/-0.02)e2 | -(1.60+/-1.35)e2 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.126 | 0.024 | (1.95+/-0.02)e2 | -(1.18+/-1.30)e2 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Nov 19, 2026
Last Site Modification: Sep 30, 2021