| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.644 | 0.020 | (2.11+/-0.02)e2 | 98.89 +/- 60.19 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 0.576 | 0.022 | (2.12+/-0.02)e2 | 69.22 +/- 96.82 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.645 | 0.036 | (1.53+/-0.04)e2 | (7.17+/-2.18)e2 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | -21.619 | 1.230 | (4.69+/-1.21)e2 | -(6.73+/-8.65)e3 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.334 | 0.038 | (2.62+/-0.04)e2 | -(1.63+/-1.38)e2 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 1.027 | 0.068 | (2.89+/-0.07)e2 | (3.86+/-5.34)e2 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 1.472 | 0.069 | (2.89+/-0.07)e2 | (1.70+/-5.36)e2 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | 1.364 | 0.067 | (2.92+/-0.07)e2 | (1.08+/-5.18)e2 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.511 | 0.026 | (2.49+/-0.03)e2 | -47.75 +/- 86.61 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.429 | 0.027 | (2.45+/-0.03)e2 | 16.38 +/- 92.95 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | 0.797 | 0.047 | (3.05+/-0.05)e2 | -(1.65+/-2.10)e2 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | 0.696 | 0.046 | (2.96+/-0.04)e2 | -(3.39+/-2.13)e2 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 5.264e-10 | 1.030e-06 | (3.45+/-0.00)e2 | (6.96+/-22.23)e-8 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.529 | 0.022 | (1.94+/-0.02)e2 | (1.94+/-1.28)e2 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.527 | 0.022 | (1.94+/-0.02)e2 | (1.41+/-1.33)e2 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Oct 24, 2026
Last Site Modification: Sep 30, 2021