| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | -0.101 | 0.020 | (2.11+/-0.02)e2 | (1.09+/-1.05)e2 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | -0.104 | 0.019 | (2.12+/-0.02)e2 | 76.71 +/- 97.83 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | -0.423 | 0.045 | (1.52+/-0.04)e2 | -52.81 +/- 224.31 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 20.419 | 1.706 | (5.26+/-1.62)e2 | -(7.42+/-9.54)e3 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.250 | 0.042 | (2.61+/-0.04)e2 | (1.74+/-1.34)e2 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | -0.182 | 0.071 | (2.88+/-0.07)e2 | 92.62 +/- 459.59 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | -0.137 | 0.071 | (2.88+/-0.06)e2 | (2.87+/-4.50)e2 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.199 | 0.069 | (2.91+/-0.06)e2 | (4.82+/-4.44)e2 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.040 | 0.028 | (2.48+/-0.03)e2 | (1.32+/-1.03)e2 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.049 | 0.024 | (2.44+/-0.02)e2 | (1.39+/-0.73)e2 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -0.448 | 0.064 | (3.03+/-0.06)e2 | 36.22 +/- 232.17 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -0.533 | 0.063 | (2.93+/-0.06)e2 | (1.68+/-2.30)e2 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 3.713e-10 | 1.027e-06 | (3.45+/-0.00)e2 | -(1.41+/-1.46)e-7 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | -0.122 | 0.020 | (1.94+/-0.02)e2 | (2.59+/-1.28)e2 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | -0.128 | 0.021 | (1.94+/-0.02)e2 | (1.80+/-1.39)e2 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Jul 04, 2026
Last Site Modification: Sep 30, 2021