| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | -0.259 | 0.025 | (2.13+/-0.02)e2 | (2.05+/-0.91)e2 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | -0.278 | 0.023 | (2.13+/-0.02)e2 | (2.59+/-0.91)e2 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | -0.568 | 0.053 | (1.53+/-0.05)e2 | (1.99+/-2.34)e2 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 2.562 | 0.578 | (6.64+/-0.54)e2 | -(5.23+/-17.99)e2 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.291 | 0.042 | (2.62+/-0.04)e2 | (2.45+/-1.32)e2 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | -0.190 | 0.073 | (2.90+/-0.07)e2 | (9.47+/-4.13)e2 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | -0.134 | 0.075 | (2.90+/-0.07)e2 | (9.00+/-4.21)e2 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.182 | 0.073 | (2.93+/-0.07)e2 | (6.69+/-4.13)e2 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | -0.083 | 0.028 | (2.49+/-0.03)e2 | (2.82+/-0.98)e2 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.032 | 0.027 | (2.45+/-0.02)e2 | (2.73+/-0.84)e2 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | 0.815 | 0.046 | (3.02+/-0.05)e2 | (3.00+/-2.07)e2 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | 0.729 | 0.045 | (2.93+/-0.04)e2 | (1.55+/-2.02)e2 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 6.221e-11 | 1.020e-06 | (3.45+/-0.00)e2 | (1.03+/-0.19)e-7 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | -0.309 | 0.029 | (1.95+/-0.03)e2 | (1.37+/-1.39)e2 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | -0.299 | 0.029 | (1.95+/-0.03)e2 | (2.40+/-1.39)e2 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Feb 03, 2026
Last Site Modification: Sep 30, 2021