Back to Top

HRCTEMP
Static Version: Max --- Last Five years

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
2ceahvpt -4.5580.065(2.88+/-0.10)e20.07 +/- 0.91KCEA RADIATOR TEMPERATURE AT CENTERNo Violation Check
2chtrpzt 0.2970.028(2.98+/-0.03)e2-0.35 +/- 1.04KCENTRAL ELECTRONICS BOX TEMPNo Violation Check
2condmxt -4.7470.070(2.81+/-0.11)e2-0.56 +/- 0.98KCONDUIT -X FACE TEMPERATURENo Violation Check
2dcentrt -4.0830.056(2.81+/-0.09)e20.07 +/- 0.72KDETECTOR HOUSING TEMP 2No Violation Check
2dtstatt -4.8320.063(2.80+/-0.11)e2-0.55 +/- 0.72KDETECTOR HOUSING TEMP 1No Violation Check
2fhtrmzt -6.0730.093(2.78+/-0.14)e2-1.41 +/- 1.47KFRONT END ELECTRONICS BOX TEMPERATURENo Violation Check
2fradpyt -5.5410.087(2.75+/-0.13)e2-1.37 +/- 1.45KFRONT END ASSEMBLY +Y AT RADIATOR CENTER TEMPNo Violation Check
2pmt1t -2.2860.038(2.89+/-0.06)e20.81 +/- 0.97KPMT 1 TEMPERATURENo Violation Check
2pmt2t -2.7710.045(2.91+/-0.07)e20.65 +/- 1.03KPMT 2 TEMPERATURENo Violation Check
2uvlspxt -2.8450.044(2.81+/-0.07)e20.11 +/- 0.82KUV LIGHT SHIELD NEXT TO SNOUT TEMPNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Feb 04, 2026
Last Site Modification: Sep 30, 2021