| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 2ceahvpt | -4.179 | 0.059 | (2.87+/-0.10)e2 | 0.12 +/- 0.88 | K | CEA RADIATOR TEMPERATURE AT CENTER | No Violation Check | |
| 2chtrpzt | 0.297 | 0.028 | (2.98+/-0.03)e2 | -0.35 +/- 1.04 | K | CENTRAL ELECTRONICS BOX TEMP | No Violation Check | |
| 2condmxt | -4.326 | 0.064 | (2.80+/-0.11)e2 | -0.67 +/- 1.00 | K | CONDUIT -X FACE TEMPERATURE | No Violation Check | |
| 2dcentrt | -3.722 | 0.051 | (2.81+/-0.09)e2 | -0.34 +/- 0.68 | K | DETECTOR HOUSING TEMP 2 | No Violation Check | |
| 2dtstatt | -4.415 | 0.057 | (2.80+/-0.10)e2 | -0.59 +/- 0.67 | K | DETECTOR HOUSING TEMP 1 | No Violation Check | |
| 2fhtrmzt | -5.567 | 0.084 | (2.78+/-0.14)e2 | -1.09 +/- 1.49 | K | FRONT END ELECTRONICS BOX TEMPERATURE | No Violation Check | |
| 2fradpyt | -5.075 | 0.078 | (2.75+/-0.13)e2 | -0.92 +/- 1.48 | K | FRONT END ASSEMBLY +Y AT RADIATOR CENTER TEMP | No Violation Check | |
| 2pmt1t | -2.047 | 0.035 | (2.89+/-0.05)e2 | 0.14 +/- 0.96 | K | PMT 1 TEMPERATURE | No Violation Check | |
| 2pmt2t | -2.501 | 0.041 | (2.90+/-0.07)e2 | 0.25 +/- 1.01 | K | PMT 2 TEMPERATURE | No Violation Check | |
| 2uvlspxt | -2.575 | 0.040 | (2.81+/-0.07)e2 | 0.15 +/- 0.78 | K | UV LIGHT SHIELD NEXT TO SNOUT TEMP | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Jul 04, 2026
Last Site Modification: Sep 30, 2021