Back to Top

HRCTEMP
Static Version: Mean --- Last Three Months

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
2ceahvpt -0.0035.984e-04(2.79+/-0.01)e2-0.73 +/- 0.38KCEA RADIATOR TEMPERATURE AT CENTERNo Violation Check
2chtrpzt -0.0046.136e-04(2.76+/-0.01)e2-0.78 +/- 0.38KCENTRAL ELECTRONICS BOX TEMPNo Violation Check
2condmxt -0.0068.700e-04(2.71+/-0.02)e2-1.14 +/- 0.48KCONDUIT -X FACE TEMPERATURENo Violation Check
2dcentrt -0.0035.110e-04(2.74+/-0.01)e2-0.78 +/- 0.30KDETECTOR HOUSING TEMP 2No Violation Check
2dtstatt -0.0026.047e-04(2.70+/-0.01)e2-0.88 +/- 0.37KDETECTOR HOUSING TEMP 1No Violation Check
2fhtrmzt -0.0070.001(2.67+/-0.02)e2-0.87 +/- 0.67KFRONT END ELECTRONICS BOX TEMPERATURENo Violation Check
2fradpyt -0.0080.001(2.65+/-0.03)e2-0.68 +/- 0.71KFRONT END ASSEMBLY +Y AT RADIATOR CENTER TEMPNo Violation Check
2pmt1t -0.0049.426e-04(2.85+/-0.02)e2-1.00 +/- 0.52KPMT 1 TEMPERATURENo Violation Check
2pmt2t -0.0049.307e-04(2.85+/-0.02)e2-0.93 +/- 0.52KPMT 2 TEMPERATURENo Violation Check
2uvlspxt -0.0076.811e-04(2.76+/-0.02)e2-0.52 +/- 0.41KUV LIGHT SHIELD NEXT TO SNOUT TEMPNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: May 23, 2026
Last Site Modification: Sep 30, 2021