Back to Top

HRCTEMP
Static Version: Min --- Last Five years

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
2ceahvpt -3.9320.055(2.85+/-0.10)e20.43 +/- 0.69KCEA RADIATOR TEMPERATURE AT CENTERNo Violation Check
2chtrpzt 0.3670.028(2.95+/-0.03)e20.60 +/- 0.96KCENTRAL ELECTRONICS BOX TEMPNo Violation Check
2condmxt -4.1240.060(2.76+/-0.11)e2-0.52 +/- 0.81KCONDUIT -X FACE TEMPERATURENo Violation Check
2dcentrt -3.4750.047(2.79+/-0.09)e20.63 +/- 0.48KDETECTOR HOUSING TEMP 2No Violation Check
2dtstatt -4.3820.060(2.76+/-0.11)e20.25 +/- 0.59KDETECTOR HOUSING TEMP 1No Violation Check
2fhtrmzt -5.4820.079(2.74+/-0.14)e2-0.07 +/- 1.01KFRONT END ELECTRONICS BOX TEMPERATURENo Violation Check
2fradpyt -5.0600.074(2.71+/-0.13)e2-0.16 +/- 1.07KFRONT END ASSEMBLY +Y AT RADIATOR CENTER TEMPNo Violation Check
2pmt1t -1.8890.033(2.86+/-0.05)e2-0.01 +/- 0.91KPMT 1 TEMPERATURENo Violation Check
2pmt2t -2.2400.037(2.87+/-0.06)e20.12 +/- 0.93KPMT 2 TEMPERATURENo Violation Check
2uvlspxt -2.3180.037(2.79+/-0.06)e2-0.23 +/- 0.70KUV LIGHT SHIELD NEXT TO SNOUT TEMPNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Sep 24, 2026
Last Site Modification: Sep 30, 2021