Back to Top

SIMELEC
Static Version: Mean --- Full Range

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
agrndadc -9.503e-054.357e-07(4.16+/-8.28)e-4(8.96+/-3.62)e-6VAnalog fround A/D convert readingNo Violation
fatabadc -7.976e-051.893e-054.99 +/- 0.01-(5.53+/-4.42)e-4VFA Tab Position Sensor A/D ConverterNo Violation
n15vadc -4.390e-041.752e-05-15.01 +/- 0.01-(8.56+/-90.19)e-7V-15V Power Supply A/D Converter ReadingNo Violation
p15vadc -5.120e-051.677e-0514.96 +/- 0.01(2.33+/-1.72)e-5V+15V Power Supply A/D Converter ReadingYellow Lower Violation: 2027.66
p5vadc 2.190e-042.754e-054.96 +/- 0.02(1.00+/-35.49)e-5V+5V Power Supply A/D Converter ReadingNo Violation
tsctabadc -3.276e-043.952e-054.97 +/- 0.030.00 +/- 0.00VTSC Tab Position Sensor A/D converterNo Violation

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Feb 04, 2026