Radiation Telecon Summary and SCS-107 on Comm: (June 1, 2025 9:08 am)
---------------------------------------------------------------------
At the 2025:153:12:30 (08:30 AM Jun 1 Sun) comm SCS-107 was observed to have run at 2025:152:05:51:32 in response to an ACIS/TXings high radiation flag.  The cause was an Earth-directed CME associated with an M8 flare Friday evening.   The transition was nominal, with science loads halted and the spacecraft and instruments in a safe configuration.

Pre-approved CAP 893B to disable SCS 29 was run as a clean-up action.

P3 rates are already down to near restart levels.  The comm passes at 153:19:30 and 154:02:30 (Jun 2, Mon at 3:30 PM or 10:30 local) is being considered for uplink of replan loads, which are expected out for review later today or early tomorrow.  Any updates will follow the 9 AM tag-up tomorrow (Monday).