See http://cxc.harvard.edu/mta/SOT_reports/sot-shift.html

Report M8953.

    Start at  2024:025:18:45 GMT
             = 1:45 pm ET January 25, 2024
    End   at  2024:025:19:45 GMT
             = 2:45 pm ET January 25, 2024


ACIS SOT Shift Report January 25, 2024

ACIS Personnel: Catherine Grant, Paul Plucinsky

PLAN
----
Run CAP1730 to start a 24 hour ECS measurement after NSM recovery. The ObsID for this measurement is 62620.  This is a 3-CCD ECS measurement.


CLD File executed:

1A_ECS3B_24H_135.CLD

SUMMARY:
--------

The CAP executed as expected.


TIMELINE (GMT day 025)
----------------------

18:47  AOS
18:48  ACIS FSW version 60, science idle, FP Temp = -106.0C
18:50  Begin SSR dump
18:55  1DPAMZT = 32.2C ; 1DPICACU = 0.78A ; 1DPICBCU = 0.94A ; 1DEICACU = 0.87A
19:02  Begin CAP 1730
19:03  SCS 107 enabled
19:04  ObsID set to 62620
19:04  1A_ECS3B_24H_135.cld uplinked
19:05  SCS-135 enabled and activated
19:06  power up command
19:07  start science
19:07  1STAT1ST = science active
19:19  Bias packets telemetering
19:20  1DPICACU = 1.09A ; 1DPICBCU = 0.60A ; 1DEICACU = 1.49A
19:25  Event data telemetering, FP Temp = -106.0C
19:27  Event data looks nominal
19:30  End