| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.484 | 0.020 | (2.13+/-0.03)e2 | -0.42 +/- 1.03 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 0.518 | 0.020 | (2.13+/-0.03)e2 | -0.36 +/- 1.05 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.888 | 0.068 | (1.59+/-0.08)e2 | -0.75 +/- 2.22 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 111.192 | 1.155 | (3.91+/-2.57)e2 | 1.15 +/- 6.14 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.757 | 0.027 | (2.64+/-0.03)e2 | -0.88 +/- 1.35 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | -0.105 | 0.055 | (2.99+/-0.06)e2 | -1.51 +/- 2.31 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | -0.112 | 0.054 | (2.99+/-0.06)e2 | -0.06 +/- 2.24 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.139 | 0.054 | (3.02+/-0.06)e2 | 0.25 +/- 2.27 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.130 | 0.024 | (2.49+/-0.02)e2 | 0.13 +/- 0.87 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.605 | 0.021 | (2.46+/-0.03)e2 | -1.53 +/- 1.07 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -0.370 | 0.057 | (3.09+/-0.07)e2 | 0.60 +/- 2.55 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -0.259 | 0.056 | (3.03+/-0.07)e2 | 1.11 +/- 2.46 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 0.120 | 0.020 | (3.45+/-0.02)e2 | (9.45+/-84.14)e-4 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.446 | 0.028 | (1.96+/-0.03)e2 | 0.11 +/- 1.14 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.488 | 0.028 | (1.96+/-0.03)e2 | -0.12 +/- 1.14 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Oct 18, 2026
Last Site Modification: Sep 30, 2021