| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.551 | 0.022 | (2.13+/-0.03)e2 | -0.28 +/- 1.02 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 0.583 | 0.022 | (2.13+/-0.03)e2 | -0.49 +/- 1.02 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 1.037 | 0.075 | (1.59+/-0.08)e2 | -0.74 +/- 2.23 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 118.536 | 1.223 | (3.78+/-2.57)e2 | 1.98 +/- 1.72 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.778 | 0.030 | (2.64+/-0.04)e2 | -2.61 +/- 1.35 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | -0.036 | 0.060 | (2.99+/-0.07)e2 | -1.31 +/- 2.30 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | -0.037 | 0.059 | (2.99+/-0.06)e2 | 1.33 +/- 2.27 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.063 | 0.059 | (3.02+/-0.06)e2 | 0.59 +/- 2.29 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.130 | 0.024 | (2.49+/-0.02)e2 | 0.13 +/- 0.87 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.649 | 0.023 | (2.46+/-0.03)e2 | -1.89 +/- 1.07 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -0.530 | 0.062 | (3.09+/-0.07)e2 | -0.27 +/- 2.46 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -0.412 | 0.060 | (3.02+/-0.07)e2 | -0.06 +/- 2.38 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 0.130 | 0.023 | (3.45+/-0.02)e2 | -0.00 +/- 0.02 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.536 | 0.031 | (1.96+/-0.04)e2 | -0.67 +/- 1.13 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.581 | 0.031 | (1.96+/-0.04)e2 | -0.26 +/- 1.15 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Jun 01, 2026