Back to Top

HRCTEMP
Static Version: Mean --- Last One Years

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
2ceahvpt 6.259e-047.340e-05(2.79+/-0.01)e20.05 +/- 0.02KCEA RADIATOR TEMPERATURE AT CENTERNo Violation Check
2chtrpzt 6.760e-047.482e-05(2.76+/-0.01)e20.05 +/- 0.02KCENTRAL ELECTRONICS BOX TEMPNo Violation Check
2condmxt 0.0011.049e-04(2.72+/-0.02)e20.08 +/- 0.03KCONDUIT -X FACE TEMPERATURENo Violation Check
2dcentrt 6.152e-046.222e-05(2.74+/-0.01)e20.04 +/- 0.02KDETECTOR HOUSING TEMP 2No Violation Check
2dtstatt 6.630e-047.661e-05(2.70+/-0.02)e2-0.02 +/- 0.02KDETECTOR HOUSING TEMP 1No Violation Check
2fhtrmzt 0.0021.271e-04(2.67+/-0.03)e20.08 +/- 0.04KFRONT END ELECTRONICS BOX TEMPERATURENo Violation Check
2fradpyt 0.0021.353e-04(2.65+/-0.03)e20.06 +/- 0.04KFRONT END ASSEMBLY +Y AT RADIATOR CENTER TEMPNo Violation Check
2pmt1t 0.0011.059e-04(2.85+/-0.02)e20.08 +/- 0.03KPMT 1 TEMPERATURENo Violation Check
2pmt2t 0.0011.052e-04(2.85+/-0.02)e20.07 +/- 0.03KPMT 2 TEMPERATURENo Violation Check
2uvlspxt 8.702e-047.948e-05(2.76+/-0.02)e20.06 +/- 0.03KUV LIGHT SHIELD NEXT TO SNOUT TEMPNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Nov 11, 2026
Last Site Modification: Sep 30, 2021