Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
2ceahvpt -0.4780.008(2.93+/-0.08)e2-0.02 +/- 0.07KCEA RADIATOR TEMPERATURE AT CENTERNo Violation Check
2chtrpzt 0.2730.004(2.93+/-0.03)e20.01 +/- 0.09KCENTRAL ELECTRONICS BOX TEMPNo Violation Check
2condmxt -0.4950.009(2.84+/-0.08)e2-(6.37+/-6325.00)e-5KCONDUIT -X FACE TEMPERATURENo Violation Check
2dcentrt -0.3990.007(2.86+/-0.07)e2-0.02 +/- 0.06KDETECTOR HOUSING TEMP 2No Violation Check
2dtstatt -0.5650.009(2.85+/-0.09)e2(8.92+/-595.10)e-4KDETECTOR HOUSING TEMP 1No Violation Check
2fhtrmzt -0.7550.011(2.85+/-0.11)e20.01 +/- 0.07KFRONT END ELECTRONICS BOX TEMPERATURENo Violation Check
2fradpyt -0.7080.011(2.82+/-0.11)e20.02 +/- 0.07KFRONT END ASSEMBLY +Y AT RADIATOR CENTER TEMPNo Violation Check
2pmt1t -0.0840.005(2.88+/-0.04)e2-0.01 +/- 0.08KPMT 1 TEMPERATURENo Violation Check
2pmt2t -0.1060.006(2.90+/-0.05)e2-0.01 +/- 0.09KPMT 2 TEMPERATURENo Violation Check
2uvlspxt -0.2420.006(2.83+/-0.05)e20.03 +/- 0.06KUV LIGHT SHIELD NEXT TO SNOUT TEMPNo Violation Check