Back to Top

HRCTEMP
Static Version: Min --- Last Three Months

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
2ceahvpt -0.0045.240e-04(2.79+/-0.01)e20.13 +/- 0.37KCEA RADIATOR TEMPERATURE AT CENTERNo Violation Check
2chtrpzt -0.0045.383e-04(2.76+/-0.01)e20.19 +/- 0.38KCENTRAL ELECTRONICS BOX TEMPNo Violation Check
2condmxt -9.181e-047.842e-04(2.71+/-0.02)e20.36 +/- 0.44KCONDUIT -X FACE TEMPERATURENo Violation Check
2dcentrt -2.507e-044.446e-04(2.74+/-0.01)e20.60 +/- 0.30KDETECTOR HOUSING TEMP 2No Violation Check
2dtstatt -1.018e-056.615e-04(2.70+/-0.02)e20.78 +/- 0.43KDETECTOR HOUSING TEMP 1No Violation Check
2fhtrmzt 3.214e-040.001(2.67+/-0.02)e21.12 +/- 0.64KFRONT END ELECTRONICS BOX TEMPERATURENo Violation Check
2fradpyt 0.0020.001(2.65+/-0.03)e21.21 +/- 0.71KFRONT END ASSEMBLY +Y AT RADIATOR CENTER TEMPNo Violation Check
2pmt1t 0.0037.827e-04(2.85+/-0.02)e20.85 +/- 0.51KPMT 1 TEMPERATURENo Violation Check
2pmt2t 0.0017.667e-04(2.85+/-0.02)e20.81 +/- 0.50KPMT 2 TEMPERATURENo Violation Check
2uvlspxt 0.0035.562e-04(2.76+/-0.01)e20.10 +/- 0.39KUV LIGHT SHIELD NEXT TO SNOUT TEMPNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Jan 30, 2026
Last Site Modification: Sep 30, 2021