MTA Monitoring Report 08/28/09 - 09/03/09

Archive of all weekly reports

Archive of monthly reports

Radiation

Quiet.

Detrended CTI

Although we have quoted CTI values of the cleanest data (FT <= -119.7 C, int time > 7000sec), the data fills these conditions are getting rare. We quote CTI temperature factor corrected ones. The values in the parentheses are CTI based on the cleanest data.

Average of ACIS-I CCDs (MnKa) slope: 1.291e-9 CTI/day (1.458e-9 CTI/day)
Detrended slope: 7.238e-9 CTI/day(7.274e-9 CTI/day)

ACIS Warm Pixels

We display all bad pixels showed up in past, and, if any, previously unknown bad pixels appeared in the last 14 days. We also list hot pixels (defined as 1000 above the average of bias background). Warm columns 509-514 are probably due to a computational artificial effect due to boundaries.


ACIS Focal Plane Temperature

SIM Movements

11 TSC moves this period
weekly average time/step 0.00118 s
mission average time/step 0.00134 s

Telemetry

New violations or new extrema are shown in blue cells.
MSID 08/28/09 08/29/09 08/30/09 08/31/09 09/01/09 09/02/09 09/03/09 yellow limits
(lower)
upper
red limits
(lower)
upper
Units Description
1DPPWRB     (7.46)         (9.0)
43.0
(8.0)
44.0
W DPA P WER B
5EPHINT 316.86 318.99 319.42 319.42 319.84   320.27 (261.0)
300.0
(258.0)
303.0
K EPHIN TEMP
HKEBOXTEMP 320.95 323.67 323.67 323.67 324.39   325.11 (268.0)
308.0
(253.0)
343.0
K EPHIN HOUSEKEEPING EBOX: TEMPERATURE (5EHSE300)
HKFBIASLEAKI 3.12 3.85 3.98 4.02 4.13 2.22 4.27 (-100.0)
2.0
(-200.0)
3.0
uA EPHIN HOUSEKEEPING F-BIAS: LEAKAGE CURRENT (5EHSE900)
TEPHIN 316.12 318.59 319.42 318.59 319.42   320.24 (260.8)
300.2
(258.0)
303.0
K EPHIN SENSOR HOUSING TEMP
4RT584T     290.01 290.01 290.01 290.01   (281.9)
290.0
(250.2)
308.0
K RT 584 - STRUT TEMP
OOBTHR05     290.06 290.06 290.14 290.06   (281.9)
290.0
(250.2)
308.0
K RT 28: HRMA STRUT


Pitch Angle and System Temperature

This is a test implementation, not all #'s have been verified.
On the weekly plots, long green ticks indicate obsid starts. The shorter orange ticks indicate rad zone events.

The following table shows the maximum temperature (in K) appeared during the observations. All data are taken between Aug 24 and Aug 31, 2009- DOY 236-243.
Pitch Angle 60 - 75 75 - 90 90 - 110 110 - 130 130 - 145
TFSSBKT1         329.6
TFSSBKT2         325.3
TEPHIN         319.4
TEIO         319.4
5EPHINT         319.4
HKEBOXTEMP         323.7
OHRTHR38         289.2
4RT568T         287.7
4PRT4AT         215.3
OOBTHR06         288.0
4RT583T         287.2
4RT586T         288.2
PLINE01T *         285.5
PLINE02T *         295.9
PLINE03T *         292.3

* PLINE temperatures are weekly minimum temps.

IRUs


Recent Observations


OBSID DETECTOR GRATING TARGET ANALYSIS ACA
11886 ACIS-236789 NONE M15 OK OK
11765 ACIS-01236 NONE SDSS J0104+0003 OK OK
11742 ACIS-01236 NONE SPT-CL 0000-5010 OK OK
11089 ACIS-235678 NONE Cygnus Loop NE Rim re-visited OK OK
11789 ACIS-012367 NONE J2241.7-5239 OK OK
10569 ACIS-23678 NONE Arp 86 OK OK
11738 ACIS-01236 NONE SPT-CL 2332-5052 OK OK
11281 ACIS-7 NONE UGC 772 OK OK
10975 ACIS-235678 NONE HR 8799 OK OK
11741 ACIS-01236 NONE SPT-CL 2343-5411 OK OK
10465 ACIS-35678 NONE ZwCl 0348 OK OK
11309 ACIS-23678 NONE NGC 7814 OK OK
11744 ACIS-01236 NONE SPT-CL 2343-5522 OK OK

Trending

This week's focus is Gratings.

Last reported on Jun 11.

Only the most interesting or representative msids are shown below. For a full listing choose the bulletted link.

Min/max envelopes in dark blue appear on the trending plots. The envelopes are 4th degree fits to the monthly minimum and maximum values for each MSID. The final polynomial form and binning are still being experimented with. We will soon add to the trending pages a report of the fits and predictions they give on future limit violations. The light blue curve is our original smoothing of all the data over 30 day moving boxcars. The green/yellow line is a linear fit to all the data; the break occurs at a limit change.