| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| deahk17 | -0.002 | 0.002 | -0.15 +/- 0.22 | 2.20 +/- 0.81 | V | DPA Ground Reference 1 | No Violation Check | |
| deahk18 | -0.012 | 0.019 | 5.08 +/- 1.78 | 1.10 +/- 0.89 | V | DPA 5V Housekeeping A | No Violation Check | |
| deahk19 | -0.003 | 0.004 | -0.14 +/- 0.35 | 1.24 +/- 0.95 | V | DPA Ground Reference 2 | No Violation Check | |
| deahk20 | -0.011 | 0.024 | 5.14 +/- 2.23 | -0.26 +/- 1.53 | V | DPA 5V Housekeeping B | No Violation Check | |
| deahk25 | 0.002 | 0.052 | 30.77 +/- 4.84 | -3.21 +/- 1.58 | V | Primary Raw DEA 28V DC | No Violation Check | |
| deahk26 | 0.012 | 0.060 | 24.85 +/- 5.54 | 2.47 +/- 11.79 | V | Primary Raw DEA 24V DC | No Violation Check | |
| deahk27 | -0.004 | 0.015 | -15.99 +/- 1.41 | 2.64 +/- 20.49 | V | Primary Raw DEA -15.5V | No Violation Check | |
| deahk28 | 0.004 | 0.002 | 15.71 +/- 0.22 | -12.37 +/- 12.19 | V | Primary Raw DEA +15.5V | No Violation Check | |
| deahk29 | -2.769e-04 | 0.015 | -6.23 +/- 1.37 | 3.45 +/- 5.17 | V | Primary Raw DEA -6V DC | No Violation Check | |
| deahk30 | 0.001 | 0.014 | 6.12 +/- 1.34 | 0.36 +/- 1.46 | V | Primary Raw DEA +6V DC | No Violation Check | |
| deahk31 | 4.705e-05 | 2.725e-05 | 0.05 +/- 0.00 | 0.06 +/- 0.20 | mAmp | Relative Dose Rad. Monitor Side A | No Violation Check | |
| deahk32 | 1.604e-04 | 0.002 | 0.01 +/- 0.16 | -0.00 +/- 0.01 | V | Interface Ground Reference | No Violation Check | |
| deahk33 | 0.003 | 0.029 | 0.07 +/- 2.72 | -0.72 +/- 0.56 | V | Backup Raw DEA 28V DC | No Violation Check | |
| deahk34 | 5.556e-05 | 1.670e-05 | -0.08 +/- 0.00 | 0.26 +/- 0.08 | V | Backup DEA 24V DC | No Violation Check | |
| deahk35 | 0.005 | 0.010 | 0.00 +/- 0.96 | 0.21 +/- 0.19 | V | Backup DEA -15.5V DC | No Violation Check | |
| deahk36 | 0.000e+00 | 0.000e+00 | (0.00+/-0.00)e0 | (0.00+/-0.00)e0 | V | Backup DEA +15.5V DC | No Violation Check | |
| deahk37 | 0.000e+00 | 0.000e+00 | (0.00+/-0.00)e0 | (0.00+/-0.00)e0 | V | Backup DEA -6V DC | No Violation Check | |
| deahk38 | 0.000e+00 | 0.000e+00 | (0.00+/-0.00)e0 | (0.00+/-0.00)e0 | V | Backup DEA +6V DC | No Violation Check | |
| deahk39 | 0.000e+00 | 0.000e+00 | (0.00+/-0.00)e0 | (0.00+/-0.00)e0 | mAmp | Relative Dose Rad. Monitor Side B | No Violation Check | |
| deahk40 | 0.000e+00 | 0.000e+00 | (0.00+/-0.00)e0 | (0.00+/-0.00)e0 | V | Ground | No Violation Check |