Back to Top

HRCTEMP
Static Version: Min --- Last Five years

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
2ceahvpt -4.5600.064(2.85+/-0.10)e20.24 +/- 0.76KCEA RADIATOR TEMPERATURE AT CENTERNo Violation Check
2chtrpzt 0.3670.028(2.95+/-0.03)e20.60 +/- 0.96KCENTRAL ELECTRONICS BOX TEMPNo Violation Check
2condmxt -4.7970.070(2.77+/-0.11)e20.48 +/- 0.86KCONDUIT -X FACE TEMPERATURENo Violation Check
2dcentrt -4.0540.055(2.80+/-0.09)e20.47 +/- 0.57KDETECTOR HOUSING TEMP 2No Violation Check
2dtstatt -5.1110.069(2.77+/-0.11)e20.49 +/- 0.66KDETECTOR HOUSING TEMP 1No Violation Check
2fhtrmzt -6.4030.091(2.75+/-0.14)e2-0.02 +/- 1.02KFRONT END ELECTRONICS BOX TEMPERATURENo Violation Check
2fradpyt -5.9130.085(2.71+/-0.13)e20.16 +/- 1.07KFRONT END ASSEMBLY +Y AT RADIATOR CENTER TEMPNo Violation Check
2pmt1t -2.2450.038(2.86+/-0.05)e20.71 +/- 0.96KPMT 1 TEMPERATURENo Violation Check
2pmt2t -2.6510.043(2.87+/-0.06)e21.24 +/- 0.99KPMT 2 TEMPERATURENo Violation Check
2uvlspxt -2.7350.042(2.79+/-0.06)e20.40 +/- 0.73KUV LIGHT SHIELD NEXT TO SNOUT TEMPNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Feb 02, 2026
Last Site Modification: Sep 30, 2021