Back to Top

HRCTEMP
Static Version: Min --- One Week

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
2ceahvpt -0.1870.007(2.78+/-0.01)e237.83 +/- 34.52KCEA RADIATOR TEMPERATURE AT CENTERNo Violation Check
2chtrpzt -0.1880.008(2.75+/-0.01)e238.45 +/- 40.06KCENTRAL ELECTRONICS BOX TEMPNo Violation Check
2condmxt -0.3270.015(2.70+/-0.01)e236.86 +/- 95.94KCONDUIT -X FACE TEMPERATURENo Violation Check
2dcentrt -0.0120.004(2.74+/-0.00)e2-10.20 +/- 22.59KDETECTOR HOUSING TEMP 2No Violation Check
2dtstatt 0.0300.010(2.69+/-0.01)e239.41 +/- 74.83KDETECTOR HOUSING TEMP 1No Violation Check
2fhtrmzt -0.3420.015(2.65+/-0.01)e2-27.18 +/- 52.98KFRONT END ELECTRONICS BOX TEMPERATURENo Violation Check
2fradpyt -0.3700.018(2.63+/-0.02)e2-14.40 +/- 72.75KFRONT END ASSEMBLY +Y AT RADIATOR CENTER TEMPNo Violation Check
2pmt1t -0.4510.015(2.84+/-0.02)e239.77 +/- 83.54KPMT 1 TEMPERATURENo Violation Check
2pmt2t -0.4450.015(2.84+/-0.02)e270.25 +/- 78.64KPMT 2 TEMPERATURENo Violation Check
2uvlspxt -0.1870.011(2.75+/-0.01)e231.46 +/- 35.95KUV LIGHT SHIELD NEXT TO SNOUT TEMPNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Jul 05, 2026
Last Site Modification: Sep 30, 2021