Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
aothrst1 1.862e+0358.362(7.23+/-7.48)e3(1.81+/-0.31)e3CNTSACCUMULATED THRUSTER ON-TIME COUNTS (RCS1 OR MUPS1)No Violation Check
aothrst2 -15.9207.534(1.80+/-8.51)e2(7.76+/-2.89)e-8CNTSACCUMULATED THRUSTER ON-TIME COUNTS (RCS2 OR MUPS2)No Violation Check
aothrst3 463.43132.913(4.00+/-3.82)e3(3.72+/-1.54)e2CNTSACCUMULATED THRUSTER ON-TIME COUNTS (RCS3 OR MUPS3)No Violation Check
aothrst4 1.021e+0348.189(5.41+/-5.78)e3(6.85+/-2.14)e2CNTSACCUMULATED THRUSTER ON-TIME COUNTS (RCS4 OR MUPS4)No Violation Check
pcm01t 3.1250.052(3.43+/-0.08)e2-0.40 +/- 2.53KPCM TEMP 01No Violation Check
pcm02t 3.1290.052(3.43+/-0.08)e2-0.96 +/- 2.50KPCM TEMP 02No Violation Check
pcm03t 3.1210.054(3.44+/-0.09)e2-1.29 +/- 2.49KPCM TEMP 03No Violation Check
pcm04t 3.1030.052(3.43+/-0.08)e2-1.70 +/- 2.48KPCM TEMP 04No Violation Check
pfdm101t -0.0520.007(2.93+/-0.01)e2-0.07 +/- 0.25KFDM1 TEMP 01No Violation Check
pfdm102t -0.1670.012(2.94+/-0.01)e2-0.01 +/- 0.45KFDM1 TEMP 02No Violation Check
pfdm201t 0.1180.008(2.90+/-0.01)e2-0.33 +/- 0.26KFDM2 TEMP 01No Violation Check
pfdm202t 0.1230.006(2.89+/-0.01)e2-0.19 +/- 0.20KFDM2 TEMP 02No Violation Check
pffp01t 1.5640.046(3.13+/-0.06)e21.81 +/- 1.79KFFP TEMP 1No Violation Check
pftank1t 2.0120.021(3.14+/-0.04)e2-0.25 +/- 0.99KFUEL TANK TEMP 01No Violation Check
pftank2t 2.1250.020(3.15+/-0.05)e2-0.24 +/- 0.96KFUEL TANK TEMP 02No Violation Check
pftankip 12.6490.135(2.08+/-0.03)e3-4.09 +/- 6.21PSIAFUEL TANK INLET PRESSURENo Violation Check
pftankop 14.9170.140(2.06+/-0.03)e3-1.95 +/- 6.65PSIAFUEL TANK OUTLET PRESSURENo Violation Check
phetankp -2.019e-08999.000(6.30+/-0.00)e2(1.16+/-6.28)e-8PSIAHE TANK PRESSURENo Violation Check
phetankt 3.4700.050(3.45+/-0.09)e2-0.57 +/- 2.14KHE TANK OUTLET TEMPNo Violation Check
phofp1t -0.1590.012(3.04+/-0.01)e20.40 +/- 0.24KHE/OX FILL PANEL TEMP 1No Violation Check
pline01t 1.0370.021(2.96+/-0.03)e20.41 +/- 0.97KPROP LINE TEMP 01No Violation Check
pline02t 2.8600.069(3.49+/-0.09)e2-2.52 +/- 2.37KPROP LINE TEMP 02No Violation Check
pline03t 1.4960.076(3.44+/-0.09)e2-0.82 +/- 2.35KPROP LINE TEMP 03No Violation Check
pline04t 2.5180.078(3.30+/-0.10)e2-3.78 +/- 3.15KPROP LINE TEMP 04No Violation Check
pline05t 2.4890.044(3.25+/-0.07)e2-0.37 +/- 2.02KPROP LINE TEMP 05No Violation Check
pline06t 2.4000.041(3.16+/-0.06)e2-0.52 +/- 1.88KPROP LINE TEMP 06No Violation Check
pline07t 1.6250.041(3.13+/-0.06)e20.70 +/- 1.65KPROP LINE TEMP 07No Violation Check
pline08t -0.0800.006(2.97+/-0.01)e20.02 +/- 0.21KPROP LINE TEMP 08No Violation Check
pline09t -0.4660.028(3.14+/-0.03)e20.92 +/- 1.17KPROP LINE TEMP 09No Violation Check
pline10t 0.1520.010(3.08+/-0.01)e20.19 +/- 0.42KPROP LINE TEMP 10No Violation Check
pline11t -0.0700.013(2.95+/-0.02)e20.51 +/- 0.76KPROP LINE TEMP 11No Violation Check
pline12t 0.7010.015(2.95+/-0.02)e20.73 +/- 0.72KPROP LINE TEMP 12No Violation Check
pline13t -0.1990.016(2.87+/-0.02)e20.59 +/- 0.55KPROP LINE TEMP 13No Violation Check
pline14t -0.0110.011(2.94+/-0.01)e2-0.13 +/- 0.42KPROP LINE TEMP 14No Violation Check
pline15t 0.2560.016(2.96+/-0.02)e20.81 +/- 0.73KPROP LINE TEMP 15No Violation Check
pline16t 1.1450.022(3.13+/-0.03)e2-1.22 +/- 1.03KPROP LINE TEMP 16No Violation Check
pm1thv1t 1.9360.076(3.67+/-0.09)e20.10 +/- 2.56KMUPS 1 THRUSTER VALVE 01 TEMPNo Violation Check
pm1thv2t 2.1310.069(3.68+/-0.09)e2-1.61 +/- 2.33KMUPS 1 THRUSTER VALVE 02 TEMPNo Violation Check
pm2thv1t 1.5750.159(3.61+/-0.18)e23.21 +/- 5.06KMUPS 2 THRUSTER VALVE 01 TEMPNo Violation Check
pm2thv2t 2.1140.204(3.55+/-0.23)e2-2.18 +/- 6.61KMUPS 2 THRUSTER VALVE 02 TEMPNo Violation Check
pm3thv1t -0.2450.010(3.08+/-0.01)e20.25 +/- 0.26KMUPS 3 THRUSTER VALVE 01 TEMPNo Violation Check
pm3thv2t -0.2380.010(3.07+/-0.01)e20.15 +/- 0.26KMUPS 3 THRUSTER VALVE 02 TEMPNo Violation Check
pm4thv1t -0.1600.019(3.07+/-0.02)e20.17 +/- 0.64KMUPS 4 THRUSTER VALVE 01 TEMPNo Violation Check
pm4thv2t -0.1250.016(3.03+/-0.02)e20.53 +/- 0.53KMUPS 4 THRUSTER VALVE 02 TEMPNo Violation Check
pmfp01t 2.4740.041(3.19+/-0.07)e2-1.34 +/- 1.90KMFP TEMP 1No Violation Check
pmtank1t 2.6550.022(3.21+/-0.06)e2-0.21 +/- 1.35KMUPS TANK TEMP 1No Violation Check
pmtank2t 2.6350.025(3.20+/-0.06)e2-0.05 +/- 1.34KMUPS TANK TEMP 2No Violation Check
pmtank3t 2.6670.025(3.21+/-0.06)e2-0.40 +/- 1.36KMUPS TANK TEMP 3No Violation Check
pmtankp 21.0950.266(9.76+/-0.50)e2-3.75 +/- 7.60PSIAMUPS TANK PRESSURENo Violation Check
pxdm01t -0.3590.021(2.91+/-0.02)e21.97 +/- 1.02KODM TEMP 01No Violation Check
pxdm02t -0.7630.031(2.96+/-0.04)e22.90 +/- 1.44KODM TEMP 02No Violation Check
pxtank1t 0.0050.006(2.99+/-0.01)e2-0.03 +/- 0.29KOX TANK TEMP 01No Violation Check
pxtank2t -0.0320.007(3.00+/-0.01)e2-0.14 +/- 0.27KOX TANK TEMP 02No Violation Check
pxtankip -6.8240.041(1.87+/-0.01)e3-0.10 +/- 1.57PSIAOX TANK INLET PRESSURENo Violation Check
pxtankop 0.0170.043(1.92+/-0.00)e3-1.15 +/- 1.97PSIAOX TANK OUTLET PRESSURENo Violation Check