Skip to the navigation links
Last modified: 28 February 2024

URL: https://cxc.cfa.harvard.edu/csc/columns/limsens.html

Limiting Sensitivity Properties


All limiting sensitivity properties returned by the CSC 2.1 Quick search interface are calculated on a HEALPix grid with pixel size 3.22 arcsec from the Stacked Observation Detections Limiting sensitivity maps data products available through CSCview. These per-stack limiting sensitivity maps are calculated as described in Characterising CSC 2.1.


Column Name Type Units Description
ra double deg ICRS right ascension of the location where the limiting sensitivity is estimated
dec double deg ICRS declination of the location where the limiting sensitivity is estimated
flux_sens_b float ergs s-1 cm-2 Estimated minimum energy flux in the ACIS broad (0.5-7.0 keV) energy band required for a point source to be detected and classified as MARGINAL at the detection position or at the query position and within the query radius
flux_sens_w float ergs s-1 cm-2 Estimated minimum energy flux HRC wide (~0.1-10.0 keV) energy band required for a point source to be detected and classified as MARGINAL at the detection position, or at the query position and within the query radius
photflux_sens_b float photons s-1 cm-2 Estimated minimum photon flux in the ACIS broad (0.5-7.0 keV) energy band required for a point source to be detected and classified as MARGINAL at the detection position or at the query position and within the query radius
photflux_sens_w float photons s-1 cm-2 Estimated minimum photon flux HRC wide (~0.1-10.0 keV) energy band required for a point source to be detected and classified as MARGINAL at the detection position or at the query position and within the query radius
flux_sens_true_b float ergs s-1 cm-2 Estimated minimum energy flux in the ACIS broad (0.5-7.0 keV) energy band required for a point source to be detected and classified as TRUE at the detection position or at the query position and within the query radius
flux_sens_true_w float ergs s-1 cm-2 Estimated minimum energy flux in the HRC wide (~0.1-10 keV) energy band required for a point source to be detected and classified as TRUE at the detection position or at the query position and within the query radius
photflux_sens_true_b float photons s-1 cm-2 Estimated minimum photon flux in the ACIS broad (0.5-7.0 keV) energy band required for a point source to be detected and classified as TRUE at the detection position or at the query position and within the query radius
photflux_sens_true_w float photons s-1 cm-2 Estimated minimum photon flux in the HRC wide (~0.1-10 keV) energy band required for a point source to be detected and classified as TRUE at the detection position or at the query position and within the query radius